Product Introduction
| Model: | constant voltage series |
| Power: | 12W max. |
| Input: | 100-240VAC 50/60Hz |
| Output Voltage: | 12V |
| Output Current: | 100MA-2000MA |
| Inrush Current: | 65 Amps max. at 230VAC/50Hz,full load |
| Leakage Current: | 2.5mA Max. at 264VAC input |
| No Load Power Consumption : | <0.5W |
| Protections: | Short Circuit /Over Current /Over Voltage/over temperature protection |
| Short Circuit Protection (SCP): | Protection to Zero Voltage |
| Over Voltage Protection (OVP): | ≤Vout*150% |
| Over Current Protection (OCP): | 110%-180% |
| Working TEMP.: | -20°C-50°C |
| Working Humidity: | 5%-90% RH non-condensing |
| Storage TEMP.,Humidity and altitude: | -40℃ ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL. |
| Certificates and approvals: | CE,EMC,RoHS,REACH |
| EMI EMISSION: |
Conducted disturbance at mains terminals:EN 55015 Radiation Test&Conduction Test: EN 55015 Magnetic Emission:EN55015:2013 Harmonic Test : EN 61000-3-2 Voltage fluctuation and Flicker Test : EN 61000-3-3 |
| EMS IMMUNITY: |
ESD Test:IEC 61000-4-2 RS Test:IEC 61000-4-3 EFT/B Immunity Test:IEC61000-4-4 Surge Immunity :IEC61000-4-5 Conduted RF Immunity: IEC 61000-4-6 Power frequency magnetic field:IEC 61000-4-11 Voltage dips and interruptions,100% reduction: IEC 61000-4-11 Voltage dips and interruptions,30% reduction: IEC 61000-4-11 |
| MTBF: | 100000 hours minimum at full load at 25℃ ambient |
| Life: | 3-5 years alternative |
| Dimension: | 59*36*26mm |
| Weight: | 93g |
| Packing: | 100PCS/CTN,36*28.5*25cm |